Change to food-grade cooling emulsion on Can Man welder
Summary
- Empty the water tank. On 2-circuit cooling unit only cold water tank has to be emptied.
 - Blow off one by one each cooling circuit in the welder. This allows to empty each circuit separately. If your welder has a 2-circuit cooling system only the circuit for the lower and upper weld roll has to be emptied.
 - Change the filter cartridge and clean the filter housing inside.
 - Fill the tank with water only, open main valve Y14, and run the system for at least one hour to flush rests of old emulsion out.
 - Empty the water tank again and clean again if necessary.
 - Fill the water tank with water (or distilled water if requested), and mix the PowerRoll™ coolant H1 in with 8 percent.
 
We recommend following maintenance procedures:
- Change the filter cartridge monthly.
 - Change the cooling emulsion yearly. Use the PowerRoll™ cooling system cleaner at any time you change the emulsion.
 - Use the PowerRoll™ cooling system decalcer after around 5 years.
 
Order numbers:
- PowerRoll™ coolant H1 (food grade), 7 Liter, 011494
 - PowerRoll™ cooling system cleaner H1 (food grade), 10 Liter, 011495
 - PowerRoll™ cooling system decalcer, 25 kg, 011496
 - Filter cartridge 50 µm, 002446
 
Safety data sheets attached
		