Eject station can-memory is always „0“ or goes down to „0“
- Check sensor on tool
- Check setting of t2 and t1
- Check input of reduce current signal. LED of input 4 of pacemaker board.
- Check the Max Gap setting. Factory setting 80%.
- For testing you can set Max Gap to 0% => function off. Attention! No correction of the memory if cans are removed before the ejection station.