Views:

Basic settings and parameters


How to make the adjustments is described in the manual.

Transformer step:               1 (if other is chosen, mention it)

Air supply:                            min. 4 bar and dry/clean! Check if there is water in the tank and the filter is still in. If yes, please mention it. It may happen that an air regulator is damaged or not working properly due to water or dirt.

Copper wire profile:           2.05 +/- 0.03 mm

Welding roller grooves:      width 2.10 mm, depth 0.40 mm. Edges should not be sharp, grind them manually!

Welding speed:                    See display frequency inverter, 50 – 55Hz (10 – 12m/min) Above 12m/min micro leakages can appear!

Welding pressure:               1.7 – 2.0 bar (35-40 daN/kg)

Related Products: CM 21