Views:

The wire continuously runs slow after machine control is "ON"


Cause:

The sensors B1 and B2, which are mounted to main machine plate, need to be readjusted.

Screen-Shot-2017-04-27-at-10.34.47-AM.png (328×247)

 

Here you have another viewpoint of the two sensors.

Screen-Shot-2017-04-27-at-10.38.41-AM.png (375×289)

 

The reason, why the wire is still running is, that a distance “x” in the picture is too big.
Therefore reduce the clearance for both sensors B1 and B2 too a minimum of 0.1mm.

Screen-Shot-2017-04-27-at-10.39.41-AM.png (379×266)

Related Products: X8