Views:

Power supply missing


Problem:

  • No error on HMI but the drives do not start when the green button “Production On” is pressed.

Causes & Resolutions:

Main power supply of 72 VDC from the Linmot controller is missing:

Probably the 15 Ampere fuse is broken

  1. Check the power supply G5 inside the control panel on the second table (see picture below).
  2. Replace the fuse

Related Products: PowerCUT