Views:

RAM battery replacement instruction 


The Pacemaker™ static welding inverter has a RAM battery for data retention and clock-buffering at power interruption/disconnection. The battery has a limited life span (about 5 years) that decreases especially without power supply (controller off). To prevent loss of data, the battery must be replaced early enough.

 

Process:

  • Switch machine power OFF
    Discharging - wait at least 5 min. before proceed with next step

 

 

 

  • Remove the Pacemaker™ cover 
    (Dispose the old battery properly)

 

 

 

  • Switch machine power ON
    (LED on Pacemaker™ board green)
    ATTENTION - DON’T TOUCH OTHER PARTS!
     

 

 

  • Remove the RAM battery carefully with extractor tool parallel to the board
    (Dispose the old battery properly)

 

 

 

  • Put on the new battery
    Ensure correct orientation (locking pins)

 

 

 

  • Check that no error message appears after the reboot
    If “User data corrupt” or “data corrupt” is displayed, please contact Can Man at spares.canman@soudronic.com

 

 

 

  • Switch machine power OFF
    Discharging - wait at least 5 min. before proceed with next step

 

 

 

  • Mount the Pacemaker™ cover


 

 

Related Products: Pacemaker