Views:

Vacuum malfunctioning 


Problem:

The suction cup malfunctioned.
Vacuum not working, constantly on or constantly blowing air instead of (sucking and then blowing) once only.

Causes & Resolutions:

  • Most likely the relay is defective and needs to be replaced.
  • The vacuum suction injector is defective and needs to be replaced.
     

Components:

KA1.2 to 1.7 Relays

Y108 / Vacuum blank feeder back
Y109 / Vacuum blank feeder front
Y110 / Vacuum first Table

Y111 / Blow off blank feeder back
Y112 / Blow off blank feeder front
Y113 / Blow off first Table

Spare Part:

003246                        Relay / terminal 1 two – way contact 

                              

 

010482                        Vacuum suction injector (Y109/Y112)

010486                        Vacuum suction injector (Y108/Y111, Y110/Y113)

Related Products: PowerCUT