Views:

The GCC stops with a fault message: "required hardware missing or faulty"


Issue

The GCC stops with a fault message: "required hardware missing or faulty".

 

Note: The number in brackets is the number of the CAN-bus adapter:

  • 0 = Kvaser
  • all others = set address at the CanBridge.


The Kvaser CAN card, Kvaser,  USB CAN-bus adapter or CAN-bridge is missing or faulty.

Remedy 

Example: Kvaser CAN card

1. Check if the can card is connected correctly within the PC.
    Picture B&R PC with SAG number 745.11108070/30

2. Replace the Kvaser CAN 

 

Example: USB CAN-bus adapter

Example: CAN bridge

 

Related Products: UNICONTROL 1, UNICONTROL 2
Comments (0)