Powder falling off, while the can body is moving through PowerCURE™
Possible cause:
- Check whether the powder already was falling off before the can bodies did enter the PowerCURE™.
 - The transport belts are not running steadily:
- Check whether the belt from the motor to gearboxes is jumping over.
 - Do not tension too much, tension till the belt is not jumping over anymore.
 
 - Take off the belt from motor and both transport belts, and check the play of both gear boxes:
- The internal worm gear might be broken.
 
 - The internal worm gear might be broken.
 - Grease the guides of the transport belts to reduce the friction.
 - Check whether the transport belts are moving straight into the guides:
- The belt is touching the left or right of the groove.
 
 - The belt is touching the left or right of the groove.
 - Check all wheels and replace the bearing when not turning smoothly.
 - Increase the transport belt speed.
- Please check the curing after increasing the speed as this might require a bit higher voltage adjustment, however the consumed energy is the same.
 
 - Please check the curing after increasing the speed as this might require a bit higher voltage adjustment, however the consumed energy is the same.
 - Check whether any screw from the frame or any of the feet has become loose.
 - Check if the motor/gearbox of the conveyor drive is grounded. Only applicable for latest model.
- If not, ground the motor/gearbox.
 
 
		