Defective Simodrive amplifier


Issue:

Press doesn't start after longer stand still powered off. Starting the press in production is not possible and errors listed below show on the HMI. The machine can start after a while or several power off/on. Other issues can be a loss of the X-axis reference and/or Y-axis can't be referenced. The Simodrive control card shows an error. 

Possible errors on HMI:

  • Axis X1: not referenced
  • Axis Y1: not referenced
  • Axis Y2: not referenced
  • NE-modul power supply not OK
  • NE-modul not ready for operation

Remedy:

  • If not referenced, reference X-axis (see related knowledge article)
  • Swap the Y-axes amplifier, if Y-axes can't be referenced. If the error moves to the other drive, a new amplifier is needed.

Important: 

Only swap the amplifier and not the controller card. The controller card has dedicated parameters loaded. 

 Miscellaneous:

The NE-modul (E/R-module) goes into an error state if one of the drives has an error on the display. Keep in mind, the above listed error also can point to a defective NE-modul. 